Hosting services
Miner Monitoring and Maintenance
Keep your miners healthy with continuous monitoring and hands-on technical care.

Monitoring
Continuous status monitoring
We monitor hashrate, temperatures, fan speeds and connectivity so issues are identified quickly.
- Hashrate and uptime tracking
- Temperature and fan alerts
- Pool connectivity checks

Maintenance
Repairs and preventive care
Technicians perform cleaning, fan and power supply replacements, firmware updates and hashboard diagnostics. Parts and advanced repairs are quoted separately where applicable.
Monitoring signals that help distinguish downtime from underperformance
Useful ASIC monitoring looks beyond whether a miner is online. Hashrate shows productive output, while temperatures and fan speed help identify cooling stress or airflow restrictions. Pool connectivity confirms communication with the configured mining endpoint. Rejected shares can indicate stale work, connection problems, or configuration issues; they should be interpreted alongside accepted shares and pool-side results. A short-lived fluctuation is not necessarily a fault. Compare each reading with the miner’s normal operating baseline, manufacturer guidance, and recent operating conditions before deciding whether intervention is necessary.
Power draw helps explain efficiency changes and unexpected shutdowns, but its source matters: a device estimate is not interchangeable with a dedicated meter reading. Error logs provide supporting evidence, such as repeated hashboard initialization failures, sensor faults, or power-supply warnings. Together, these seven signals—hashrate, temperatures, fan speed, pool connectivity, rejected shares, power draw, and error logs—support more useful diagnosis than a single dashboard status. Records should identify timestamps, affected equipment, and actions taken so recurring faults can be distinguished from isolated events.
Included vs. paid services: what to verify
These are illustrative service categories, not a statement of Teraminerhosting’s inclusions. The hosting agreement defines the exact scope, authorization requirements, exclusions, and charges; prices are quote-only.
| Service | Typically included | Typically billed separately |
|---|---|---|
| Routine monitoring | Usually included within the agreed monitoring scope. | Custom dashboards, reporting, or integrations may be quoted separately. |
| Basic remote troubleshooting | Usually included for initial status checks and fault review. | Extended investigation or specialist diagnostics may be quoted separately. |
| Reboots and configuration checks | Usually included when routine and authorized. | Firmware recovery or nonstandard configuration work may be quoted separately. |
| Preventive cleaning and inspection | May be included on an agreed maintenance schedule. | Deep cleaning, disassembly, or exceptional contamination may be quoted separately. |
| Hardware repairs and replacement parts | Initial fault identification may be included. | Parts, board-level work, and repair labor are generally quoted separately. |
| Warranty and RMA coordination | Basic documentation assistance may be included. | Packing, shipping, handling, and manufacturer-excluded work may be quoted separately. |
| Post-repair testing | Basic verification may accompany an approved repair. | Extended testing or specialist validation may be quoted separately. |
A repair procedure with clear approval points
A documented repair workflow should separate routine troubleshooting from chargeable work and preserve evidence before changes are made.
- 01
Detect and record the issue
Identify the affected miner, capture the alert and timestamp, and compare current readings with its baseline. Record whether the problem affects one device, multiple devices, or only pool-side reporting.
- 02
Perform remote diagnosis
Review connectivity, pool settings, hashboard status, power readings, and error logs where available. Check for shared infrastructure or pool issues before attributing a fault to the miner itself.
- 03
Evaluate reboot or firmware action
Preserve logs before an authorized reboot. Consider firmware changes only after checking model compatibility, configuration backups, warranty implications, and recovery options. Repeated rebooting should not substitute for identifying a persistent fault.
- 04
Conduct an on-site inspection
If remote checks are inconclusive, physical inspection can assess connectors, fans, contamination, and visible damage. Equipment must be safely isolated before internal work; hazardous electrical diagnosis requires appropriately qualified personnel.
- 05
Obtain customer approval for parts
Present the diagnosis, proposed parts, labor scope, warranty status, and available alternatives. Obtain documented authorization for chargeable work under the agreement before ordering parts or proceeding with a paid repair.
- 06
Repair or replace
Complete the approved work using compatible components and applicable manufacturer procedures. Record part identifiers and retain replaced components when required for warranty, customer ownership, or return arrangements.
- 07
Test under operating load
Confirm startup, hashboard detection, stable temperatures, fan operation, pool connectivity, and accepted shares. Compare performance with the expected configuration rather than treating successful power-on as proof of a complete repair.
- 08
Report the outcome
Provide a service record covering findings, work completed, parts used, test results, and unresolved limitations. Distinguish a confirmed resolution from a temporary recovery that still requires observation or further diagnosis.
Preventive maintenance should follow condition, not just a calendar
Preventive maintenance starts with trends: rising temperatures at comparable load, changing fan behavior, and recurring errors can justify inspection before a shutdown occurs. For air-cooled equipment, attention commonly centers on dust accumulation, heatsink airflow, fan condition, and intake restrictions. Cleaning methods should follow manufacturer guidance, with power isolated and appropriate electrostatic precautions. Avoid treating aggressive compressed air, chemical cleaners, or unnecessary disassembly as universal solutions. Poor cleaning technique can damage components or move contamination deeper into the assembly instead of removing it.
Liquid-cooled equipment needs a different checklist. Depending on the design, inspection may cover coolant compatibility, leaks, flow, pressure, filters, pumps, or heat-exchanger condition. Hydro and immersion systems should not share an interchangeable maintenance procedure. Inspection intervals should reflect manufacturer requirements, environmental conditions, equipment history, and actual readings rather than an arbitrary schedule. Keep dated records of cleaning, configuration changes, and component replacements. These records help show whether an intervention improved operation and reduce the risk of repeatedly applying a remedy that does not address the underlying cause.
Warranty and RMA handling without avoidable surprises
Before opening equipment or authorizing third-party repair, verify the applicable warranty terms with the seller or manufacturer. Coverage can depend on purchase documentation, serial numbers, delivery dates, operating conditions, and previous modifications. Firmware changes or unauthorized repairs may affect eligibility, depending on those terms. A useful warranty file includes proof of purchase, the device identifier, fault logs, photographs where relevant, and a concise troubleshooting history. Warranty eligibility is not the same as an approved claim; the responsible warranty provider determines coverage after reviewing the case.
Return merchandise authorization, or RMA, usually requires instructions before shipment. Confirm whether the complete miner or only a component should be returned, how it must be packaged, and who is responsible for shipping, insurance, and handling charges. Record tracking information and identifiers so returned equipment can be matched to the original asset. The agreement should also clarify who communicates with the warranty provider and approves uncovered work. Repair and transit downtime can reduce mining output, and mining revenue is not guaranteed. Evaluate repair expense against replacement options without assuming future earnings will recover the cost.
FAQ
Common questions
How quickly are faults addressed?
Response targets are defined in your hosting agreement. [Placeholder: response time]
Who pays for replacement parts?
Replacement parts are typically charged to the equipment owner. Details are set out in the hosting agreement.
Why can pool hashrate differ from the miner’s dashboard?
A miner typically reports a local performance estimate, while a pool estimates hashrate from submitted shares over a measurement window. Share variability, reporting delays, connection interruptions, and rejected work can create differences. Compare readings over comparable periods and review accepted shares before diagnosing a hardware problem from a brief mismatch.
Should an intermittently failing hashboard be rebooted repeatedly?
Repeated reboots may temporarily restore operation without resolving the cause. Save error logs and note when the fault occurs, including temperature and load conditions. Persistent failures warrant diagnosis of the board, connections, power supply, and configuration. If there are signs of overheating or electrical damage, stop operating the equipment pending qualified inspection.
What should a repair authorization specify?
A useful authorization identifies the miner, proposed work, approved parts, labor scope, and spending limit or quoted total. It should explain whether further approval is required if diagnosis reveals additional damage. Also clarify the disposition of replaced parts, any repair warranty, and what charges apply if the equipment cannot be repaired.
Does an RMA approval mean all related expenses are covered?
Not necessarily. RMA authorization generally permits the return process; it does not automatically confirm warranty coverage or payment of every associated expense. Shipping, insurance, packaging, diagnostic charges, and handling may have separate terms. Confirm those responsibilities in writing and ask what happens if inspection finds an excluded fault or no reproducible defect.
Ready to Host Your ASIC Miners?
Share your equipment details and our team will prepare a customised hosting quotation.