Hosting Cost Calculator
Estimate energy use and cost using a rate per kWh you enter. This is an illustration only — it is not a Teraminerhosting price. Request a quote for actual pricing.
Formula: watts × 24 × 30 ÷ 1000 × rate (30-day month = 720 hours), × uptime.
- Total load
- 3.50 kW
- Energy per month (720 h)
- 2,520 kWh
- Per day
- $5.88
- Per month (30 days)
- $176.40
- Per year
- $2,146.20
- Per miner, per month
- $176.40
Illustration only, using the rate you enter — this is not a Teraminerhosting price.
Get an exact quote for this setupHow to calculate hosting energy costs
Start with electrical power, not hashrate. Watts describe how quickly a miner consumes energy; kilowatt-hours describe the energy consumed over time. For continuous operation during a 30-day month, use: monthly energy cost = watts × 24 × 30 ÷ 1,000 × rate per kWh. Dividing by 1,000 converts watts to kilowatts. A 30-day month contains 720 hours, so the same calculation can be written as kilowatts × 720 × rate.
To estimate less than continuous operation, multiply that result by an operating-time factor: estimated energy cost = watts × 720 ÷ 1,000 × rate × operating-time factor. For example, 95% is entered as 0.95. This factor represents the share of the period when the miner draws the assumed power. It is a planning input, not an uptime promise. If equipment still consumes power while idle, include that consumption separately rather than treating every non-mining hour as zero.
Use the input wattage for the exact model and operating mode you intend to run. Firmware settings, power limits, ambient conditions, and cooling requirements can change consumption. Manufacturer specifications are useful for planning, but measured consumption provides a better basis once equipment is operating. Keep the electricity rate separate from other charges unless a quote explicitly combines them. The calculator estimates costs from your inputs; it does not establish contractual billing terms.
Worked example: ten Antminer S21 miners
All figures below are illustrations, not Teraminerhosting prices. Assume each Antminer S21 draws 3,500 W continuously, with an illustrative electricity rate of $0.07/kWh and no additional charges.
| Calculation | Method | Illustrative result |
|---|---|---|
| Power per miner | 3,500 W ÷ 1,000 | 3.5 kW |
| Monthly energy per miner | 3.5 kW × 720 hours | 2,520 kWh |
| Monthly energy cost per miner | 2,520 kWh × $0.07/kWh | $176.40 |
| Monthly energy cost for ten miners | $176.40 × 10 | $1,764.00 |
| Daily energy cost for ten miners | 3.5 kW × 10 × 24 hours × $0.07/kWh | $58.80 |
| Annual energy cost for ten miners | $58.80 × 365 days | $21,462.00 |
Read the example as an energy budget, not a bill
The monthly and annual figures use different calendar lengths deliberately. The monthly example covers exactly 30 days, while the annual example covers 365 days, or 8,760 hours. Multiplying the monthly total by twelve produces $21,168, which covers only 360 days. The remaining five days add $294, bringing the annual energy estimate to $21,462. For a calendar-month budget, replace 720 hours with the actual number of days in that month multiplied by 24.
The example also assumes constant power draw and an operating-time factor of 1.00. Applying a factor of 0.95 would reduce the estimated monthly energy for ten miners to 23,940 kWh and the illustrative energy cost to $1,675.80, assuming zero consumption during the remaining time. That adjustment does not necessarily reduce every invoice item. Fixed fees, reserved-power charges, or minimum commitments may follow different rules if they appear in the agreement.
What the energy calculation does not include
Repairs and replacement parts are outside the watts-times-hours calculation. A failed fan, power supply, control board, or hashboard can create a separate expense, along with diagnostic labor where applicable. Do not assume maintenance labor and replacement hardware have identical coverage. When reviewing a quote, identify which services are included, which require approval, and which are charged separately. A repair reserve can help with budgeting, but it should remain distinct from the calculated energy expense.
Shipping and setup are also separate budget categories unless expressly included in a quote. Freight, packaging, insurance, return shipping, and equipment handling can affect the cost of placing miners into service or removing them later. Setup may involve inspection, configuration, and connection work. Treat one-time expenses separately from recurring monthly expenses so the first-month total does not become your assumed ongoing cost. Hardware purchase costs are not included in this energy-only estimate either.
Taxes and any applicable duties are not captured by the energy formula. Their treatment depends on the transaction and relevant requirements, so confirm whether quoted amounts include or exclude them. Cooling electricity, network services, monitoring, and other operating expenses may be bundled or itemized under a hosting agreement. The calculation cannot determine that structure. Use the written scope to avoid both missing a charge and counting an included service twice in your budget.
Why an actual hosting quote can differ
A calculator simplifies the relationship between power, time, and an entered rate. A quote must also define the equipment and service scope. Exact model variants, operating settings, unit count, and cooling method can affect electrical and installation requirements. Air-cooled, hydro-cooled, and immersion configurations should not be compared solely by miner wattage: auxiliary equipment may consume additional energy. Establish whether the quoted billing basis measures miner consumption alone or includes an allocation for supporting systems.
Commercial terms can change the result even when the equipment stays the same. A proposal may use metered energy, a fixed recurring charge, or a combination of charges. Contract length, minimum commitments, deposits, billing periods, and treatment of downtime can affect either the recurring bill or cash required upfront. These are general quote-review considerations, not statements of Teraminerhosting terms. Teraminerhosting prices are quote-only; the illustrative rate above is not an offered hosting rate.
Turn the estimate into a comparable budget
Use the same assumptions for every option you compare.
- 01
Record the technical inputs
List model, unit count, watts per unit, operating mode, calendar period, and expected operating-time factor. Label measured values separately from specifications.
- 02
Separate recurring and one-time costs
Keep energy, recurring service charges, setup, shipping, taxes, and repair allowances visible as separate budget lines.
- 03
Check billing assumptions
Match each estimate to the quote’s metering boundary, included services, minimum charges, and downtime provisions before comparing totals.
- 04
Evaluate revenue separately
Mining revenue is not guaranteed. Network difficulty, asset prices, pool fees, and actual hashing performance affect returns independently of the energy calculation.
FAQ
Calculator questions
Can I calculate electricity cost from a miner’s hashrate alone?
No. Hashrate measures computational output, not electricity consumption. You also need power draw or an efficiency specification. If efficiency is expressed in joules per terahash, multiplying it by hashrate in terahashes per second gives watts. Use matching units and specifications for the same operating mode, then convert watts into energy over your chosen period.
Should I use nameplate wattage or measured power?
Use the manufacturer’s specified input power for an initial estimate, allowing for any stated tolerance. For an operating budget, measured consumption at the relevant billing point is more useful. Confirm what the meter includes: a miner-only reading and a reading that also captures cooling equipment are not directly comparable.
Does rejected share percentage belong in the energy operating-time factor?
Not directly. A miner can draw normal power while submitting rejected or stale shares, so reduced pool-side performance does not necessarily mean reduced electricity use. Base the energy factor on power-consuming operating time. Assess accepted shares and effective hashrate separately when estimating mining output and revenue.
How should I budget for miners with different power ratings?
Calculate each model group separately using its wattage, unit count, and expected operating hours, then add the energy totals. Apply the relevant billing rate to each group if terms differ. Avoid using a simple average wattage unless it is weighted by the number of units and their operating time.
Will a temporary shutdown reduce my entire hosting invoice?
Not necessarily. A shutdown may reduce metered energy consumption, but fixed service charges, minimum commitments, or reserved-power charges can remain payable if the agreement provides for them. Equipment may also consume standby power. Check the contract’s billing and downtime provisions rather than applying a single reduction percentage to the whole invoice.
Is a lower electricity estimate enough to determine profitability?
No. Energy is only one expense, and mining revenue is not guaranteed. A profitability estimate also needs hardware costs, other hosting charges, pool fees, repairs, and assumptions about network difficulty and asset prices. Test multiple revenue and cost scenarios instead of treating a single calculator result as a predicted return.
Ready to Host Your ASIC Miners?
Share your equipment details and our team will prepare a customised hosting quotation.